{"title":"Gas Masks \u0026 Respirators for Industrial \u0026 Personal Protection","description":"\u003cp data-start=\"755\" data-end=\"826\"\u003e\u003cstrong data-start=\"755\" data-end=\"824\"\u003eAdvanced Gas Masks \u0026amp; Respirators for Maximum Breathing Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"828\" data-end=\"1147\"\u003eAt Lion Tools Mart, we offer a wide range of \u003cstrong data-start=\"873\" data-end=\"902\"\u003egas masks and respirators\u003c\/strong\u003e designed to protect against harmful gases, fumes, dust, and airborne particles. Ideal for industrial workers, technicians, and safety-conscious individuals, our products ensure safe breathing and reliable protection in hazardous environments.\u003c\/p\u003e","products":[{"product_id":"jon-bhandari-dust-mask-industrial-d-033","title":"JON BHANDARI DUST MASK INDUSTRIAL D-033","description":"\u003cp\u003e\u003cstrong\u003eDescription :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"a-unordered-list a-vertical a-spacing-none\"\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eType: Mask Half Mask\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eSuitable For: Construction Air-supplied Respirator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eSelf closing valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eLight weight soft grey color\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eAnti-pollution exhalation valve \u0026amp; Nose clip for sealed nose and mouth area\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JON BHANDARI","offers":[{"title":"Default Title","offer_id":31110793723948,"sku":"","price":255.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/3450\/8068\/products\/jon-bhandari-dust-mask-industrial-d-033.jpg?v=1610351092"},{"product_id":"karam-ffp2-disposable-painting-respirator-with-headband-and-exhalation-valve-rfh-22-0v-mask-nose-protection","title":"Karam FFP2 Disposable Painting Respirator with Headband and Exhalation Valve RFH 22+0V Mask | Nose Protection","description":"\u003ch2\u003e\u003cstrong\u003eKaram FFP2 NR D Disposable Painting Respirator with Headband and Exhalation Valve RFH 22+0V Mask | Nose Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification: EN 149:2001+A1:2009, IS 9473:2002\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eThe RFH22+OV respirator offers dual-layer defense against organic vapors, oil, and water particles. It features an activated carbon non-woven layer for superior vapor protection and exceeds 98% filtration efficiency for particulates and bacteria. Designed for comfort, it includes an ultrasonically sealed headband and a flexible nose clip. The full-face coverage ensures a pressure-balanced, secure fit, making it ideal for demanding environments. Reliable and efficient, the RFH22+OV combines safety and comfort in one high-performance protective mask.\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty: 1 Year from the date of Invoice against any manufacturing defects.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eKEY FEATURES:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003eDual-layer defence against organic vapours, oil \u0026amp; water particles.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eUltrasonically sealed headband \u0026amp; flexible nose clip for comfort.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eFull-face coverage with pressure-balanced fit.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eActivated carbon non-woven layer for protection against organic vapours.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eExceeds 98% particulate and bacterial filtration.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"product-table\" style=\"width: 100%;\" height=\"716\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eVital Test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.3437%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eRequirement as per Standard\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 25.0786%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eKARAM Respirator\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eParticulate Filtering Efficiency\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.3437%;\"\u003e\n\u003ch4\u003eRequirement as per standard- 94%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 25.0786%;\"\u003e\n\u003ch4\u003eExceeds 98%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eBreathing Resistance\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.3437%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003eInhalation Flow- 30 l\/min: Should be less than 0.7 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eInhalation Flow- 95 l\/min: Should be less than 2.4 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eExhalation Flow- 160 l\/min: Should be less than 3.0 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 25.0786%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003e0.5 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003e2.1 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003e2.6 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eTotal Inward Leakage\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.3437%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003eThe arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 8%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eThe total inward leakage of all 50 subjects against the requirement of atleast 46 subjects should not be greater than 11%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 25.0786%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003e5.0%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003e6.0%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eCO\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eContent of Inhalation Air\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.3437%;\"\u003e\n\u003ch4\u003eCarbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 25.0786%;\"\u003e\n\u003ch4\u003e\u0026lt; 0.6%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eFlammability\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.3437%;\"\u003e\n\u003ch4\u003eThe face respirator when subject to pass the flame once at the specified speed should not continue to burn after removal of flame\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 25.0786%;\"\u003e\n\u003ch4\u003eKARAM Respirator does not continue to burn after removal of flame\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eBacterial Filtering Efficiency\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.3437%;\"\u003e\n\u003ch4\u003eBacterial filtering efficiency should be \u0026gt;90%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 25.0786%;\"\u003e\n\u003ch4\u003e\u0026gt; 98%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"KARAM Safety","offers":[{"title":"Default Title","offer_id":48390070337786,"sku":null,"price":65.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/3450\/8068\/files\/PaintingRespiratorRFH22_0VMask.jpg?v=1772200975"},{"product_id":"karam-ffp2-nr-d-disposable-welding-respirator-with-headband-and-exhalation-valve-rfh32-ov-nose-protection","title":"Karam FFP2 NR D Disposable Welding Respirator with Headband and Exhalation Valve RFH32+OV | Nose Protection","description":"\u003ch2\u003e\u003cstrong\u003eKaram FFP2 NR D Disposable Welding Respirator with Headband and Exhalation Valve RFH32+OV | Nose Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification: EN 149:2001+A1:2009, IS 9473:2002\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eThe KARAM RFH32+OV is a specialized disposable respirator designed for welding and hot-work environments. It features a flame-retardant outer layer, an activated carbon filter for organic vapor protection, and \u0026gt;98% filtration efficiency. The soft, adjustable headband ensures a snug fit, while the padded, reinforced nose clip minimizes leakage. One-way ventilation reduces heat and CO₂ buildup during intense physical activity. Its ultrasonically sealed construction adds strength and comfort across full-shift use. Ideal for torch cutting, soldering, and brazing, RFH32+OV is a go-to mask for professionals demanding safety, breathability, and superior particle resistance.\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty: 1 Year from the date of Invoice against any manufacturing defects.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eKEY FEATURES:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003eShields against welding fumes, smoke, and organic vapours.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eFlame-retardant outer with activated carbon pre-filter.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eUltrasonically sealed nose clip and adjustable headband.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eErgonomic design contours to face with full coverage.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eOffers smooth breathing with \u0026gt;98% filtration efficiency.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"product-table\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eVital Test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.7818%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eRequirement as per Standard\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 27.6405%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eKARAM Respirator\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eParticulate Filtering Efficiency\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.7818%;\"\u003e\n\u003ch4\u003eRequirement as per standard- 94%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 27.6405%;\"\u003e\n\u003ch4\u003eExceeds 98%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eBreathing Resistance\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.7818%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003eInhalation Flow- 30 l\/min: Should be less than 0.7 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eInhalation Flow- 95 l\/min: Should be less than 2.4 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eExhalation Flow- 160 l\/min: Should be less than 3.0 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 27.6405%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003e0.5 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003e2.1 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003e2.6 mbar\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eTotal Inward Leakage\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.7818%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003eThe arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 8%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eThe total inward leakage of all 50 subjects against the requirement of atleast 46 subjects should not be greater than 11%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 27.6405%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003e5.0%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003e6.0%\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eCO\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eContent of Inhalation Air\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.7818%;\"\u003e\n\u003ch4\u003eCarbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 27.6405%;\"\u003e\n\u003ch4\u003e\u0026lt; 0.6%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eFlammability\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.7818%;\"\u003e\n\u003ch4\u003eThe face respirator when subject to pass the flame once at the specified speed should not continue to burn after removal of flame\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 27.6405%;\"\u003e\n\u003ch4\u003eKARAM Respirator does not continue to burn after removal of flame\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003ctd style=\"width: 19.8556%;\"\u003e\n\u003ch4\u003eBacterial Filtering Efficiency\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.7818%;\"\u003e\n\u003ch4\u003eBacterial filtering efficiency should be \u0026gt;90%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 27.6405%;\"\u003e\n\u003ch4\u003e\u0026gt; 98%\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"KARAM Safety","offers":[{"title":"Default Title","offer_id":48390082887930,"sku":null,"price":70.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/3450\/8068\/files\/WeldingRespiratorRFH32_0VMask4.jpg?v=1772201626"}],"url":"https:\/\/www.liontoolsmart.com\/collections\/gas-masks-respirators.oembed","provider":"Lion Tools Mart","version":"1.0","type":"link"}