Karam FFP2 Disposable Painting Respirator with Headband and Exhalation Valve RFH 22+0V Mask | Nose Protection

Product Code:

Availability:In stock

Rs. 65/- 65

Qty

Ask about this product

Karam FFP2 NR D Disposable Painting Respirator with Headband and Exhalation Valve RFH 22+0V Mask | Nose Protection

Certification: EN 149:2001+A1:2009, IS 9473:2002

The RFH22+OV respirator offers dual-layer defense against organic vapors, oil, and water particles. It features an activated carbon non-woven layer for superior vapor protection and exceeds 98% filtration efficiency for particulates and bacteria. Designed for comfort, it includes an ultrasonically sealed headband and a flexible nose clip. The full-face coverage ensures a pressure-balanced, secure fit, making it ideal for demanding environments. Reliable and efficient, the RFH22+OV combines safety and comfort in one high-performance protective mask.

Warranty: 1 Year from the date of Invoice against any manufacturing defects.

KEY FEATURES:

  • Dual-layer defence against organic vapours, oil & water particles.

  • Ultrasonically sealed headband & flexible nose clip for comfort.

  • Full-face coverage with pressure-balanced fit.

  • Activated carbon non-woven layer for protection against organic vapours.

  • Exceeds 98% particulate and bacterial filtration.

PRODUCT SPECIFICATIONS:

Vital Test

Requirement as per Standard

KARAM Respirator

Particulate Filtering Efficiency

Requirement as per standard- 94%

Exceeds 98%

Breathing Resistance

  • Inhalation Flow- 30 l/min: Should be less than 0.7 mbar

  • Inhalation Flow- 95 l/min: Should be less than 2.4 mbar

  • Exhalation Flow- 160 l/min: Should be less than 3.0 mbar

  • 0.5 mbar

  • 2.1 mbar

  • 2.6 mbar

Total Inward Leakage

  • The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 8%

  • The total inward leakage of all 50 subjects against the requirement of atleast 46 subjects should not be greater than 11%

  • 5.0%

  • 6.0%

CO2 Content of Inhalation Air

Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)

< 0.6%

Flammability

The face respirator when subject to pass the flame once at the specified speed should not continue to burn after removal of flame

KARAM Respirator does not continue to burn after removal of flame

Bacterial Filtering Efficiency

Bacterial filtering efficiency should be >90%

> 98%